Rinnai Error Code 11 | Common Causes and Step-by-Step Fixes

A Rinnai error code 11 signifies an ignition failure—which means your tankless water heater is unable to spark or detect a flame. This prevents the unit from heating water and is displayed when the ignition sequence fails.


🔍 Common Causes and Step-by-Step Fixes

1. Gas Supply Issues

  • The gas valve may be fully or partially closed, or the gas type/pressure may be incorrect or inconsistent.

  • Ensure the valve is fully open, gas matches your unit’s specification, and inlet gas pressures meet the manufacturer’s guidelines (e.g., 5″–10.5″ W.C. for natural gas, 8″–13.5″ W.C. for propane).

  • Purge the gas line to remove trapped air after installation.

2. Igniter Malfunction

  • The igniter might not generate a spark due to dirt, misalignment, broken wiring, or wear.

  • Inspect wiring, clean the igniter if dirty, and ensure it’s mounted correctly with a proper gasket. Replace if it’s damaged or fails to spark.

3. Faulty Flame Rod (Sensor)

  • The flame rod may be loose, dirty, cracked, or improperly wired

  • Clean it gently, ensure it’s tightly mounted, and replace the gasket after maintenance. Replace the rod entirely if corrosion or damage is visible

4. Venting or Airflow Problems

  • Blocked or improperly installed intake/exhaust vents can disrupt combustion.

  • Inspect both intake and exhaust venting, confirming clearance and clearing any obstructions to maintain proper airflow.

5. Control Board or Wiring Issues

  • Damaged wiring or defects on the PC/control board may disrupt ignition pressure or signal.

  • Visually inspect components for damage or loose connections. If needed, use a multimeter for voltage/resistance checks (see Rinnai spec ranges). Replace the board if it’s faulty.

6. Additional Diagnostics

  • Power off and reset the unit (via control panel or breaker), then restart to clear errors—as this may resolve temporary glitches.

  • If the unit has firmware support, updating it can sometimes address underlying control logic issues.

Also Read : Lotto Result July 30 2025 Philippines Today


✅ Troubleshooting Checklist

ComponentWhat to Inspect or Do
Gas SupplyEnsure gas valve is open; check type (natural vs propane) and pressure levels
IgniterInspect wiring, alignment; clean or replace if no spark
Flame RodConfirm secure mounting, clean surface, replace if damaged
VentingClear intake/exhaust vents; confirm installation and proper airflow
Control Board/WiringCheck for loose or corroded connections; verify voltage/resistance to gas valve
Unit ResetPower-cycle to clear transient faults; restart to retry ignition cycle
Firmware (if available)Update to latest version for any control improvements

⚠️ Safety and Professional Help

  • These tasks often involve gas lines, high voltage, and internal components—which can be dangerous if mishandled.

  • If you’re uncomfortable or lack experience with electrical and plumbing systems, it’s strongly recommended to call a certified Rinnai technician.

  • Using proper tools like a multimeter to check ignition voltage or gas pressure may be necessary.


✅ Final Summary

  • Error 11 = “No ignition”, typically caused by issues related to gas supply, igniter, flame rod, venting, or control circuitry.

  • Start with basic checks (gas and airflow), clean or reseat ignition components, and power-cycle the unit.

  • If the error persists, seek professional repair to safely diagnose and fix the core issue.

Be the first to comment